Status: exploratory / pre-implementation Related phase: Phase 8 — ESP32 devices Current platform priority: Phase 2 — dashboard and persistence

Purpose

This document captures early design principles for Pomona's future physical edge-device layer.

Pomona is an offline-first, modular, safety-constrained agriculture platform. The hardware layer should extend the existing sensor ingestion, reasoner, automation, and deterministic safety architecture without allowing models or LLMs to directly control physical actuators.

These notes are informed by community discussions around DIY hydroponic controllers, greenhouse automation, sensor redundancy, irrigation safety, and open-source controller designs.

Nothing described here represents an adopted hardware design yet.

Design goals

The future Pomona edge hardware should:

  • operate locally without requiring cloud connectivity;
  • use inexpensive and widely available microcontrollers such as ESP32;
  • expose open, documented sensor and actuator interfaces;
  • communicate with Pomona Core through a simple local protocol such as MQTT;
  • tolerate network loss, process crashes, and device reboots;
  • fail to a safe physical state;
  • separate sensing, decision-making, and actuation;
  • make hardware faults observable by the software platform;
  • support manual maintenance and emergency operation;
  • remain modular rather than require one large all-purpose controller PCB.

Pomona should not depend on a specific hydroponic system topology. The same contracts should eventually support hydroponic, greenhouse, irrigation, aquaponic, and other controlled-agriculture deployments.

Proposed architecture

A possible architecture is:

                         Pomona Core
                 Raspberry Pi / PC / Mac
                            │
                           MQTT
                            │
               ┌────────────┴────────────┐
               │                         │
        Sensor Node                 Actuator Node
           ESP32                       MCU
               │                         │
     ┌─────────┼─────────┐       ┌──────┼──────┐
     │         │         │       │      │      │
    pH        EC       Temp     Pump   Valve  Aeration
     │                   │
   Level               Flow

Sensor and actuator responsibilities should remain logically separate even when early prototypes use a single ESP32.

This separation allows future systems to distribute devices across multiple physical zones without changing the Pomona Core architecture.

Hardware safety boundary

Pomona's deterministic safety layer remains the final software authority. However, software safety alone is not sufficient. Critical physical protections should exist below the application layer.

The desired hierarchy is:

Model / LLM
    │
    ▼
Reasoner
    │
    ▼
Automation suggestion
    │
    ▼
Deterministic safety checker
    │
    ▼
Actuator command gate
    │
    ▼
Device firmware validation
    │
    ▼
Hardware interlock
    │
    ▼
Physical actuator

A failure in a higher layer must not bypass protections in a lower layer.

Operating modes

Future Pomona hardware should expose explicit operating states.

Example:

AUTOMATIC
MANUAL
MAINTENANCE
EMERGENCY_STOP
FAULT

Suggested semantics:

AUTOMATIC Normal Pomona operation. Commands may be accepted only after deterministic safety validation.

MANUAL Human-controlled operation. Safety limits still apply.

MAINTENANCE Automation is suspended while hardware is being inspected, cleaned, calibrated, or serviced.

EMERGENCY_STOP Physical actuator power is disabled. Software must never be able to override this state.

FAULT The device has detected a condition that prevents safe automatic operation.

Physical emergency stop

A future reference controller should consider a physical, latching emergency stop.

The E-stop should disable actuator power independently of:

  • Pomona Core;
  • MQTT;
  • the ESP32 application;
  • reasoner output;
  • automation rules.

Example:

Pomona Core
     │
    OFF
     │

ESP32
     │
    OFF
     │

E-STOP ──────── physically disables actuator power

Software may observe the E-stop state but must not be capable of clearing it.

Sensor priorities

Sensor selection should prioritize failure detection rather than simply maximizing the number of measurements.

Tier 1 — core sensors

Initial reference hardware should investigate:

water_temperature
water_level
low_water_switch
flow_rate
ph
ec

These provide the minimum useful picture for hydroponic and irrigation monitoring.

Tier 2 — reliability sensors

Potential additional sensors:

reservoir_mass
pump_current
ambient_temperature
ambient_humidity

These measurements are particularly useful because they can reveal system failures rather than only environmental conditions.

Tier 3 — specialized sensing

Future deployments may optionally support:

dissolved_oxygen
orp
additional_water_chemistry
light / PAR
substrate sensors

These should not become requirements for the base Pomona hardware contract.

Redundant sensing

Pomona should support redundant sensors when the redundancy provides useful failure detection.

For example:

continuous_level_sensor
+
low_level_float_switch

The continuous sensor is useful for telemetry and trends. The float switch can provide a simple independent safety signal.

Example:

reported_level = 52%
low_level_switch = ACTIVE

should not be silently accepted. It should produce something similar to:

SENSOR_CONFLICT

This data can feed both deterministic validation and Pomona's sensor-quality reasoning layer.

Flow-based failure detection

Flow measurement is particularly valuable for irrigation systems.

Combining:

pump_command
valve_command
flow_rate
reservoir_level

allows several failures to be detected deterministically.

Example:

pump_command = ON
flow_rate = 0

Possible interpretation:

BLOCKAGE
PUMP_FAILURE
EMPTY_RESERVOIR
SENSOR_FAILURE

Another example:

pump_command = OFF
flow_rate > threshold

Possible interpretation:

STUCK_VALVE
SIPHONING
LEAK
FLOW_SENSOR_FAULT

These conditions should normally be identified by deterministic rules before any AI reasoning is considered.

Reservoir mass monitoring

A load cell under the reservoir is worth evaluating as an optional sensor.

Reservoir mass over time can provide:

  • water consumption estimates;
  • leak detection;
  • unexpected water-loss detection;
  • refill verification;
  • additional digital-twin observations.

Example:

expected_loss:
1.8 L/day

observed_loss:
7.2 L/hour

could immediately generate a critical water-loss condition.

This may eventually provide useful input for digital-twin and irrigation-risk models.

Sensor quality

The edge-device contract should expose enough metadata for Pomona to distinguish a biological event from a sensor problem.

Sensor packets should eventually support information such as:

device_id
sensor_id
measurement
unit
timestamp
sequence
status
calibration_timestamp

Possible quality states:

VALID
MISSING
STALE
SUSPECT
CONFLICTING
DISCONNECTED

Sensor-quality classification should complement deterministic sanity checks, not replace them.

Device communication

MQTT is the preferred initial transport because Pomona already uses MQTT internally.

Possible telemetry structure:

pomona/device/<device_id>/telemetry
pomona/device/<device_id>/status
pomona/device/<device_id>/fault
pomona/device/<device_id>/ack

Potential command path:

pomona/device/<device_id>/command

Commands should use a strict allowlisted schema.

Example:

{
  "command_id": "abc123",
  "actuator": "irrigation_pump_1",
  "action": "ON",
  "max_duration_seconds": 20
}

Arbitrary code or arbitrary natural-language commands must never reach device firmware.

Command acknowledgement

Actuator commands should eventually have explicit acknowledgements.

Example:

REQUESTED
ACCEPTED
EXECUTING
COMPLETED
REJECTED
FAULT

The platform must not assume:

command sent == physical action completed

Device state must be observable independently.

Local device protections

Possible firmware-level protections include:

watchdog
command timeout
maximum actuator runtime
stale-command rejection
low-water blocking
duplicate-command protection
boot-safe actuator state
network-loss recovery

Outputs should default to a safe state during reboot. For irrigation equipment, this generally means:

pump = OFF
valve = CLOSED

unless a particular validated hardware design requires otherwise.

Hardware interlocks

Some protections should exist independently from firmware.

Examples:

LOW WATER
    │
    └── hardware interlock ──> pump disabled

or:

E-STOP
    │
    └── actuator supply disabled

This means a software crash, stuck process, or compromised network connection does not automatically create an unsafe physical state.

Failure scenarios to test

Any Pomona reference controller should eventually have a bench-validation matrix.

At minimum:

ESP32 reboot
Pomona Core crash
MQTT disconnect
Wi-Fi disconnect
sensor disconnect
stale sensor data
contradictory sensors
pump running with zero flow
unexpected flow while pump is off
reservoir loss
stuck relay
power interruption
device restart
emergency stop
maintenance mode

The expected behavior for every failure should be documented before field deployment.

Chemical dosing boundary

Automatic nutrient, fertilizer, pesticide, pH-adjustment, or other chemical dosing is intentionally outside the current Pomona actuator scope.

Pomona reasoners may produce advisory information such as:

EC is below the expected range.

Possible action:
Review nutrient concentration.

Human review required.

They must not directly produce commands such as:

run nutrient pump for 7 seconds

Chemical recommendations and physical chemical dosing are separate safety domains.

This restriction remains in place even if external controller designs include peristaltic dosing pumps.

AI boundary

Models may help with:

sensor-quality classification
tomato risk
water / irrigation risk
nutrient / pH-EC interpretation
daily summaries
digital-twin scenarios

Models must not bypass:

deterministic rules
command allowlists
device safety constraints
human approval
hardware interlocks

The desired rule remains:

AI can advise. Deterministic systems decide whether a physical command is allowed.

Reference hardware strategy

Pomona should not immediately attempt to design one monolithic controller PCB.

A better progression is:

1. Hardware contracts
2. ESP32 sensor prototype
3. MQTT telemetry
4. Fault simulation
5. Read-only physical deployment
6. Irrigation actuator prototype
7. Deterministic safety tests
8. Hardware interlocks
9. Reference PCB

This keeps hardware development aligned with the existing software platform instead of forcing the software architecture around an early PCB design.

External collaboration

DIY hydroponic controller projects are useful potential collaboration points, especially when they explore:

  • open-source PCB design;
  • ESP32 sensor interfaces;
  • electrical isolation;
  • relay and MOSFET design;
  • physical emergency stops;
  • maintenance modes;
  • irrigation flow sensing;
  • redundant water-level sensing;
  • pump failure detection;
  • modular sensor/actuator nodes.

Before integrating an external hardware project, Pomona should evaluate:

license
schematics availability
firmware availability
component availability
electrical safety
isolation
failure behavior
MQTT compatibility
device identity
command acknowledgement
maintenance status

External projects should initially be treated as design references or collaboration opportunities rather than assumed dependencies.

Proposed Phase 8 decomposition

The current roadmap lists Phase 8 as ESP32 devices.

A future implementation could divide it into:

Phase 8.1 — Sensor node contract

Define:

telemetry schema
device identity
sensor identity
timestamps
quality metadata
MQTT topics
device health

Phase 8.2 — ESP32 sensor reference

Initial read-only hardware supporting a limited sensor set. No actuator control required.

Phase 8.3 — Hardware safety contract

Define:

maintenance mode
E-stop
watchdog
default-safe outputs
low-water interlock
command timeout

Phase 8.4 — Irrigation actuator node

Support only explicitly allowlisted irrigation actuators.

Phase 8.5 — Failure detection

Implement deterministic handling for:

no-flow
unexpected-flow
sensor disagreement
stale telemetry
reservoir loss
device disconnect

Phase 8.6 — Bench validation

Test physical and software failure scenarios before any broader deployment.

Current decision

No external hydroponic controller has been adopted by Pomona. No PCB design has been selected. No external controller should currently be described as a Pomona integration.

Community controller projects are being studied to improve the future Phase 8 hardware contract and identify potential open-source collaborators.

The immediate Pomona priority remains the existing software roadmap. Hardware development should begin only when the platform contracts are stable enough that hardware can implement them rather than define them.